title: "Commands"
description: "Gateway-supported ONFUSE Connect commands, parameters, results, and technician precautions."
space: "ONFUSE Connect"
url: "https://docs.onfuse.ch/connect/diagnosis/commands"
updated: "2026-11-18"
---

:::danger[Administrator access only]
Direct command access is reserved for administrators. Lift calls, resets, maintenance changes and access-code changes require an authorized service procedure.
:::

The Gateway executes **Device Actions** from Connect. Some come from **Gateway → Settings → Tools**, others from controller, floor, update or backend workflows. Check the final result in **Actions**. **Open** means queued.

<br>

## Commands in Gateway tools

| Command | Result |
| --- | --- |
| `tts` | Saves the server-generated spoken announcement. Enter its text in Connect. |
| `update_operation_profile` | Fetches and applies the assigned [Operation Profile](/connect/setup/operation-profile). |
| `reset_user_pin` | Clears the Gateway-local user PIN only. |
| `reboot_gateway` | Restarts the Gateway. Wait for it to reconnect before checking status. |
| `request_factory_reset` | Opens a 10-minute window for on-site confirmation with **FUN**. [Factory reset procedure](/connect/setup/gateway#factory-reset) |

<br>

## Updates and diagnostic data

| Command | Result |
| --- | --- |
| `ota_update` | Installs the newest eligible Gateway software. |
| `ota_update_cabin` | Updates registered Smart Displays. Each must have connected and identified itself at least once. |
| `get_event_data` | Retrieves up to 256 KiB of valid JSON events from a reachable controller and stores them with the action result. |

<br>

## Controller commands

Requires a reachable, supported controller and the correct controller settings in the Operation Profile.

| Command | Parameters | Result |
| --- | --- | --- |
| `call_elevator` | `floor`, `door` | Requests an inside call. Doors A/B/C use `1`/`2`/`3`. Use `255` for all doors. |
| `enable_maintenance_mode` | None | Enables maintenance mode. |
| `disable_maintenance_mode` | None | Disables maintenance mode. |
| `change_floor_name` | `floor`, `description` | Changes the floor label and refreshes Gateway information. |
| `change_elevator_number` | `number` | Changes the controller’s elevator number. |
| `change_build_year` | `build_year` | Changes the controller’s build year. |
| `remote_reset` | None | Requests a reset, waits about two minutes and refreshes Gateway information. Verify the controller’s actual state. |

Use a numeric `floor` and text for `number`, `build_year` and `description`.

<br>

## Gateway-local door settings

| Command | Parameters | Result |
| --- | --- | --- |
| `change_door_description` | `floor`, `door`, `description` | Saves a door description locally. Alias: `change_floor_description`. |
| `change_door_passcode` | `floor`, `door`, `passcode` | Saves the passcode in Gateway secure storage. Aliases: `change_floor_passcode`, `change_door_pass`, `change_floor_pass`. Older actions may use `pass`. |

Use a numeric floor and door side A, B or C. Keep passcodes out of screenshots, logs and support messages.

Unknown keys fail, including the older `reset_admin_pin`, `change_name_override` and `change_build_year_override`. [Hardware checks](/connect/diagnosis/debugging-information-for-technicians)