title: "Debugging Information for Technicians"
description: "Technician checks for Gateway, Display, PoE cabling, and standard RJ45 wire termination."
space: "ONFUSE Connect"
url: "https://docs.onfuse.ch/connect/diagnosis/debugging-information-for-technicians"
updated: "2026-11-18"
---

Record the symptom and time before changing the installation.

<br>

## Identify the correct ports

| Device | Port | Use |
| --- | --- | --- |
| Gateway | **POE** | Smart Display or display-side switch |
| Gateway | **Ethernet (LAN)** | Lift controller |
| Smart Display | **RJ45 with POE Input** | Power and local data |
| Smart Display | **Second RJ45** | Debugging only |

For two Displays, power the UniFi switch only through its **802.3at PoE input**. Check both **802.3af outputs** and the total power budget. [Gateway ports and buttons](/connect/setup/gateway)

<br>

## Terminate and test an RJ45 cable

1. **Disconnect PoE** before cutting or terminating. Use four-pair cable and compatible RJ45 plugs. Use the same scheme at both ends, either T568A or T568B.
2. Follow the numbered pins on the plug or tool. Viewing the opposite side reverses the apparent order. The table gives **T568B**.

| Pin | T568B conductor |
| --- | --- |
| 1 | White/orange |
| 2 | Orange |
| 3 | White/green |
| 4 | Blue |
| 5 | White/blue |
| 6 | Green |
| 7 | White/brown |
| 8 | Brown |

3. Seat all eight conductors, crimp with the correct tool and secure the jacket under the strain relief.
4. Test **1→1 through 8→8** for opens, shorts and reversals. Use split-pair detection as well as continuity. Verify PoE mode and power budget against the equipment specifications. Wire colors alone cannot identify voltage or polarity.

[Ubiquiti pin diagram](https://dl.ui.com/guides/toughcable/TOUGHCable_PRO_QSG.pdf) · [Fluke wiring codes](https://www.flukenetworks.com/knowledge-base/application-or-standards-articles-copper/differences-between-wiring-codes-t568a-vs)

<br>

## Check the installation

**Display dark.** Check **Display POE IN**, the Gateway PoE port or switch output, and the available power. Try a tested cable.

**Display powered, no live data.** Find the Display and controller in **Gateway → Connected Devices**. Check the switch uplink, cable wire map, local addressing and controller IP in the Operation Profile.

**Gateway offline in Connect.** In **Testing**, check the SIM, antenna, operator and signal. Use **Operation Profile → Server connection** to test reachability. **Cloud Connection** shows the configured server and device identity.

**Emergency-call issue.** In **Testing**, check inputs, battery and last successful test call. Use **Activate Test Call** only within the site’s approved procedure. [Phone keypad controls](/connect/diagnosis/dtmf-signals)

For support, record device IDs, software versions, LED state, signal, exact error and time. Keep API secrets and PINs out of support material.