title: "Field guide to Connect, Gateway and Smart Display"
space: "ONFUSE Connect"
url: "https://docs.onfuse.ch/connect/setup/first-setup-in-the-field"
updated: "2026-11-18"
---

:::note[Authorized personnel only]
Wiring changes, settings and controller tests can affect elevator movement and emergency calling. Follow the site’s approved procedures.
:::

Have the work order ready with the elevator number, site address and organization.

<br>

## Where to start

| Task | Open in ONFUSE Connect |
| --- | --- |
| Register a Gateway | **Devices → + → Gateway** |
| Check a lift | **Devices → search by elevator number → Gateway** |
| Open the controller locally | **Connect → Gateway** while beside the lift’s Gateway |
| Check a cabin screen | **Gateway → Devices**, then verify at the Smart Display |

<br>

## Register a new Gateway

### Open Devices

Stand beside the powered Gateway and allow about one minute for startup. Enable Bluetooth and internet on your phone. Sign in with your work account and verification code if prompted. Tap **Devices → + → Gateway**.

<img src="/files/connect-field-setup-01-add.png" alt="Devices tab with the add menu open and Gateway selected." width="250" style="display:block;width:250px;max-width:100%;height:auto;margin:1.5rem auto 2rem" />

### Scan for the Gateway

Allow Bluetooth, nearby-device and location permissions when prompted. Tap **Scan** and wait about eight seconds. Under **Discovered devices**, select the identifier for this lift.

<img src="/files/connect-field-setup-02-scan.png" alt="Bluetooth scan showing a Gateway under Discovered devices." width="250" style="display:block;width:250px;max-width:100%;height:auto;margin:1.5rem auto 2rem" />

If the list is empty, check Gateway power, move closer and scan again. Restore denied permissions in your phone’s app settings.

### Enter the elevator number and choose the organization

In **Name**, enter the work order’s **elevator number**, for example **20200000**. Enter the **Address**, choose a **Language** if needed, check the organization and tap the **right arrow**.

<img src="/files/connect-field-03-details-20200000.png" alt="Setup form showing elevator number 20200000, address, language and organization." width="250" style="display:block;width:250px;max-width:100%;height:auto;margin:1.5rem auto 2rem" />

Confirm the prepared configuration and tap **Finish**. Connect selects the only available choice automatically. If yours is missing, check the organization, then ask the office to confirm the assignment.

### Check the device list

Under **All devices**, match the number and address to the work order. Keep the Gateway powered while it downloads its settings. On return visits, search by elevator number. Pull down to refresh or long-press the record to **Pin to top**.

<img src="/files/connect-field-04-registered-20200000.png" alt="Registered elevator 20200000 in All devices." width="250" style="display:block;width:250px;max-width:100%;height:auto;margin:1.5rem auto 2rem" />

### Create the automatic announcement

Open **Gateway → Settings → Tools → Set automatic announcement**. With **Standard** on, check the elevator number, address and language in the preview. For different wording, turn **Standard** off and enter a **Custom announcement**. Tap **Save** and verify playback during the approved call test.

<br>

## Emergency buttons in the elevator shaft

| Button location | Connection |
| --- | --- |
| Inside the cabin | **Smart Display → MicroMatch**. The Display connects to the Gateway over PoE. |
| Cabin roof, under the cabin, shaft pit or controller room | Optional technician button → **Edge Gateway digital input** |
| On the emergency phone in the controller room | **Edge Gateway → MicroMatch** |

<img src="/files/elevator-shaft-cabin-alarm.png" alt="Shaft cutaway. Red lines connect alarm buttons to their inputs. Dashed blue links the cabin Smart Display to the controller-room Gateway over PoE." width="465" style="display:block;width:465px;max-width:100%;height:auto;margin:1.5rem auto 2rem" />

Hold a configured **Gateway** button for **3 seconds** to start the outgoing emergency call. The cabin button normally uses the same hold. Its [alarm filter](/connect/setup/operation-profile#cabin-alarm-filter) can extend the hold during confirmed travel.

<br>

## Connect the elevator controller

Use the guide for the installed model. [MPK411 setup](/connect/setup/controllers/mpk411) · [Core setup](/connect/setup/controllers/core)

<br>

## Read the Gateway on your phone

Open **Devices → your lift → Gateway**. Match the elevator number before taking action. Check the address, software version, cellular signal and battery where available. Under **Devices**, match each installed Display’s ID and version.

<img src="/files/connect-field-05-gateway-20200000.png" alt="Gateway view with live indicator, device status and an attached Smart Display." width="250" style="display:block;width:250px;max-width:100%;height:auto;margin:1.5rem auto 2rem" />

### Is the reading live?

**Purple lightning** means fresh Gateway data. **Gray lightning** or **Showing the last saved reading** means you should check the timestamp. A green stripe in the device list can represent cloud contact up to about two hours ago.

### Is the controller reporting?

Tap **Controller**. Check the elevator number, floor, direction and available states. If both cabin and app lack floor data, check controller power and the Ethernet link even if the Gateway is live.

- **Test a destination.** Selecting and confirming a floor or entrance requests lift movement. Only run an authorized test and verify arrival at the intended floor.
- **Edit a label.** Long-press a floor name or entrance description.
- **Read events.** Open **Controller → Tools → Get event log** and refresh the request. Tools also offers maintenance mode, build year and elevator number for assigned service work.

<br>

## Bring the Smart Display online

### At the cabin

1. For one screen, connect **Gateway POE → Display POE IN**. For two screens, use the powered switch layout in [Display setup](/connect/setup/display).
2. On a new Display, follow **Quick start → Select the gateway → update → Restart**. The standard local Gateway address is `192.168.1.1`. The selection screen cannot save a different address.
3. Match the Display ID in **Connected Devices** on the physical Gateway and in **Gateway → Devices** in Connect. During an authorized trip, verify the actual cabin floor and direction.

Cabin floor data works locally during a cloud outage. If the screen shows **OUT OF ORDER**, check the Display-to-Gateway link, then the Gateway-to-controller link.

### In Connect

A Display’s own entry in **All devices** opens its **last saved reading**. Check the timestamp for floor, speed and state. Pull down to refresh. **Not available** means no reading was recorded. Use the live Gateway view and cabin screen for current status.

<img src="/files/connect-field-07-display-20200000.png" alt="Display detail with the timestamp and floor from the last saved reading." width="250" style="display:block;width:250px;max-width:100%;height:auto;margin:1.5rem auto 2rem" />

Tap the pencil to edit the cloud **Name** or **Address**. Where available, the floor table offers entrance calls and descriptions, and **Tools** offers build year and elevator number. Check the result on site before repeating a queued request.

### On the Smart Display itself

Tap the **date or time → Settings** and enter the four-digit Display PIN if prompted. Set brightness and everyday volume here. For call audio, use **Managed by Edge Gateway → Administrator → Emergency volume → Save**.

Under **Administrator → Interfaces**, **COP (normal)** shows lift information and **COP with input** adds floor selection. Where enabled, **Floors** edits shared labels, **Access** manages entrance-specific Floorpass codes and **Reservation** sets the reservation duration.

<br>

## Connect locally over Gateway Wi-Fi

1. Enable phone Wi-Fi. Stand beside the Gateway and open **Connect → Gateway**. Local access works without cloud sign-in.
2. Hold **FUN** for at least **3 seconds** and release **before 6 seconds**. Enter all **eight spoken digits**, including any leading zero.
3. Accept the network prompt. On Android, enable location services and allow precise location if requested.
4. In **Controllers**, select the expected elevator number. Refresh if needed. Go back from the list to release the local connection. **Devices** returns to cloud monitoring.

<img src="/files/connect-field-08-wifi.png" alt="Local Gateway connection screen with an eight-digit PIN field." width="250" style="display:block;width:250px;max-width:100%;height:auto;margin:1.5rem auto 2rem" />

If joining fails, check permissions and request a fresh PIN beside the intended Gateway. Connect favors the strongest nearby ONFUSE network.

<br>

## Change settings and update devices

In **Devices → your lift → Settings**, verify **Name**, address, coordinates and language against the work order, then open **Tools**.

<img src="/files/connect-field-06-tools-20200000.png" alt="Gateway Settings with separate update actions for Gateway and Displays." width="250" style="display:block;width:250px;max-width:100%;height:auto;margin:1.5rem auto 2rem" />

| Tool | What to check |
| --- | --- |
| **Update Gateway software** | Confirm the update. After restart, check the result and Gateway version. |
| **Update display software** | Targets all registered Displays that have identified themselves at least once. After restart, check each version. |
| **Update Cabin logo** | Check the organization’s logo on each cabin screen. |
| **Set automatic announcement** | Review the text, save and verify playback during the approved call test. |
| **Update operation profile** | Retrieves an assigned office change. Check **Actions**. |
| **Reset user PIN** | Clears the Gateway’s local PIN. A Display PIN requires its own service procedure. |
| **Reboot** | Restarts the Gateway. |
| **Reset to factory settings** | Physical confirmation erases local data. Recommission the Gateway afterward. |

### Did the action finish?

In **Gateway → Actions → See more**, open the request and tap **Refresh**. **Open** or **In progress** means pending. For **Error**, record the response and time before retrying. For **Completed**, verify the change on the device. **Alerts** includes test-call results.

<br>

## Before leaving the site

- Record the elevator number, site address, Gateway and Display IDs, and software versions.
- Check fresh Gateway and controller data. Verify floor and direction in each cabin.
- Follow the approved emergency-phone test. Confirm two-way audio with the operator. Record **Gateway → Testing → Last successful test call** and the matching Connect alert for the automatic test.
- Check all requested actions. Record unresolved faults with the failed connection, message and time. Keep credentials and PINs out of screenshots and handover notes.

[Troubleshoot power, live data or cloud connection](/connect/diagnosis/debugging-information-for-technicians)