title: "Gateway"
description: "Connect, register, configure, and verify an ONFUSE Edge Gateway."
space: "ONFUSE Connect"
url: "https://docs.onfuse.ch/connect/setup/gateway"
updated: "2026-11-18"
---

:::note[Authorized personnel only]
Gateway wiring and configuration affect lift operation and emergency calling.
:::

The **Edge Gateway** (order code `EDGE-GW`) links the lift controller, emergency-call hardware, cabin Displays and ONFUSE Connect.

<br>

## Before you begin

Have the antenna, supplied power cable and an active **4FF SIM with voice and data**. Disable the SIM PIN. Sign in to Connect and have an administrator prepare an enabled [Operation Profile](/connect/setup/operation-profile).

<br>

## Connect and register the Gateway

1. Disconnect power, insert the SIM and close the cover. Attach the antenna and connect the approved **24 V DC** barrel supply.
2. Allow about one minute for startup. Check reception using the [front-panel LEDs](#front-panel-leds).
3. In Connect, open **Devices → + → Gateway → Scan**. Select the Gateway. Enter the **elevator number** (e.g. **20200000**) in **Name** and enter the site address. Confirm the organization, tap the right arrow, select the prepared configuration and finish. [Field setup screenshots](/connect/setup/first-setup-in-the-field)
4. Check the Gateway appears in Connect. On the Gateway, verify the applied **Operation Profile** and version.

<br>

## Local connections

<img src="https://onfuse.ch/wp-content/uploads/2025/09/IO.jpg" alt="Edge Gateway connector panel with LAN, PoE Display, alarm inputs, power and antenna connections." width="480" style="display:block;width:480px;max-width:100%;height:auto;margin:1.5rem auto 2rem" />

| Gateway port | Connects to |
| --- | --- |
| **POE Display** | One Smart Display directly or a PoE-powered switch for two. [Display wiring and switch power requirements](/connect/setup/display) |
| **Ethernet (LAN)** | Elevator controller. [MPK411](/connect/setup/controllers/mpk411) · [Core](/connect/setup/controllers/core) |
| **Digital input** | Optional shaft or controller-room alarm contact. |
| **MicroMatch** | Alarm button on the emergency phone. |
| **24 V barrel**, **SMA female** | Gateway power and external cellular antenna, respectively. |
| **USB-C** | Updates. |
| **HDMI**, **USB-A** | Debugging. |

On backup power, the Gateway supplies the connected Smart Display(s) for **at least one hour**.

<br>

## Physical buttons

| Button | Action |
| --- | --- |
| **PWR** | Powers on the Gateway. Pressing it again while powered has no effect. |
| **FUN**, under 3 seconds | Shows cellular reception and fetches pending Connect actions. |
| **FUN**, 3 to under 6 seconds | Starts ONFUSE Wi-Fi and speaks an eight-digit PIN. Enter all digits in **Connect → Gateway**, including leading zeros. |
| **FUN**, hold at least 30 seconds, then release | Confirms a [factory reset](#factory-reset) requested in Connect while its 10-minute window is open. |
| **R**, press and release | Reboots and keeps saved settings. |

<br>

## Front-panel LEDs

Press **FUN** for under three seconds. Read all three LEDs together. If the modem cannot return a reading, the previous colors stay on.

| Cellular reception | LED 1 | LED 2 | LED 3 |
| --- | --- | --- | --- |
| No signal or no cell reported | 🔴 Red | 🔴 Red | 🔴 Red |
| Weak | 🟠 Orange | 🟠 Orange | 🔴 Red |
| Fair | 🟠 Orange | 🟠 Orange | 🟠 Orange |
| Good | 🟢 Green | 🟢 Green | 🟠 Orange |
| Strongest | 🟢 Green | 🟢 Green | 🟢 Green |

During registration, three green LEDs also indicate that the Gateway is advertising over Bluetooth. Tap **Scan** in Connect to find it.

<br>

## Configure and verify

- **Operation Profile** — Check the profile and version. Use **Server connection** to test reachability and **Refresh profile from server** after office changes. The applied profile is stored locally for offline startup.
- **Connected Devices** — Match the controller and each Display to the installation.
- **Testing** — Review battery, signal, operator, inputs and last successful test call. Follow the site’s approved procedure for test calls.
- **Cloud Connection** — Shows the server and device identity. Keep credentials out of screenshots and support messages.

[Cable checks](/connect/diagnosis/debugging-information-for-technicians) · [Gateway commands and results](/connect/diagnosis/commands)

<br>

## Factory reset

A factory reset erases the Gateway’s local credentials, settings and stored files, including the saved announcement. Have the elevator number, site address and organization ready for setup afterward.

1. **Request the reset in Connect.** Open **Devices**, select the Gateway and check its elevator number. Go to **Settings → Tools → Reset to factory settings** and confirm.
2. **Confirm on the Gateway.** Once the Gateway receives the request, you have **10 minutes** to complete this step. Press and hold the physical **FUN** button continuously for **at least 30 seconds**, then **release it** before the window expires. The Gateway erases its local data and reboots. If the window expires, send a new request from Connect.
3. **Set up the Gateway again.** Follow [First setup in the field](/connect/setup/first-setup-in-the-field) to register the Gateway and restore its announcement. Verify the applied profile, controller and Displays, then follow the site’s approved emergency-call test before returning the installation to service.