ONFUSE Connect

ONFUSE Connect

Field guide to Connect, Gateway and Smart Display

Have the work order ready with the elevator number, site address and organization.


Where to start

Task Open in ONFUSE Connect
Register a Gateway Devices → + → Gateway
Check a lift Devices → search by elevator number → Gateway
Open the controller locally Connect → Gateway while beside the lift’s Gateway
Check a cabin screen Gateway → Devices, then verify at the Smart Display

Register a new Gateway

Open Devices

Stand beside the powered Gateway and allow about one minute for startup. Enable Bluetooth and internet on your phone. Sign in with your work account and verification code if prompted. Tap Devices → + → Gateway.

Devices tab with the add menu open and Gateway selected.

Scan for the Gateway

Allow Bluetooth, nearby-device and location permissions when prompted. Tap Scan and wait about eight seconds. Under Discovered devices, select the identifier for this lift.

Bluetooth scan showing a Gateway under Discovered devices.

If the list is empty, check Gateway power, move closer and scan again. Restore denied permissions in your phone’s app settings.

Enter the elevator number and choose the organization

In Name, enter the work order’s elevator number, for example 20200000. Enter the Address, choose a Language if needed, check the organization and tap the right arrow.

Setup form showing elevator number 20200000, address, language and organization.

Confirm the prepared configuration and tap Finish. Connect selects the only available choice automatically. If yours is missing, check the organization, then ask the office to confirm the assignment.

Check the device list

Under All devices, match the number and address to the work order. Keep the Gateway powered while it downloads its settings. On return visits, search by elevator number. Pull down to refresh or long-press the record to Pin to top.

Registered elevator 20200000 in All devices.

Create the automatic announcement

Open Gateway → Settings → Tools → Set automatic announcement. With Standard on, check the elevator number, address and language in the preview. For different wording, turn Standard off and enter a Custom announcement. Tap Save and verify playback during the approved call test.


Emergency buttons in the elevator shaft

Button location Connection
Inside the cabin Smart Display → MicroMatch. The Display connects to the Gateway over PoE.
Cabin roof, under the cabin, shaft pit or controller room Optional technician button → Edge Gateway digital input
On the emergency phone in the controller room Edge Gateway → MicroMatch
Shaft cutaway. Red lines connect alarm buttons to their inputs. Dashed blue links the cabin Smart Display to the controller-room Gateway over PoE.

Hold a configured Gateway button for 3 seconds to start the outgoing emergency call. The cabin button normally uses the same hold. Its alarm filter can extend the hold during confirmed travel.


Connect the elevator controller

Use the guide for the installed model. MPK411 setup · Core setup


Read the Gateway on your phone

Open Devices → your lift → Gateway. Match the elevator number before taking action. Check the address, software version, cellular signal and battery where available. Under Devices, match each installed Display’s ID and version.

Gateway view with live indicator, device status and an attached Smart Display.

Is the reading live?

Purple lightning means fresh Gateway data. Gray lightning or Showing the last saved reading means you should check the timestamp. A green stripe in the device list can represent cloud contact up to about two hours ago.

Is the controller reporting?

Tap Controller. Check the elevator number, floor, direction and available states. If both cabin and app lack floor data, check controller power and the Ethernet link even if the Gateway is live.

  • Test a destination. Selecting and confirming a floor or entrance requests lift movement. Only run an authorized test and verify arrival at the intended floor.
  • Edit a label. Long-press a floor name or entrance description.
  • Read events. Open Controller → Tools → Get event log and refresh the request. Tools also offers maintenance mode, build year and elevator number for assigned service work.

Bring the Smart Display online

At the cabin

  1. For one screen, connect Gateway POE → Display POE IN. For two screens, use the powered switch layout in Display setup.
  2. On a new Display, follow Quick start → Select the gateway → update → Restart. The standard local Gateway address is 192.168.1.1. The selection screen cannot save a different address.
  3. Match the Display ID in Connected Devices on the physical Gateway and in Gateway → Devices in Connect. During an authorized trip, verify the actual cabin floor and direction.

Cabin floor data works locally during a cloud outage. If the screen shows OUT OF ORDER, check the Display-to-Gateway link, then the Gateway-to-controller link.

In Connect

A Display’s own entry in All devices opens its last saved reading. Check the timestamp for floor, speed and state. Pull down to refresh. Not available means no reading was recorded. Use the live Gateway view and cabin screen for current status.

Display detail with the timestamp and floor from the last saved reading.

Tap the pencil to edit the cloud Name or Address. Where available, the floor table offers entrance calls and descriptions, and Tools offers build year and elevator number. Check the result on site before repeating a queued request.

On the Smart Display itself

Tap the date or time → Settings and enter the four-digit Display PIN if prompted. Set brightness and everyday volume here. For call audio, use Managed by Edge Gateway → Administrator → Emergency volume → Save.

Under Administrator → Interfaces, COP (normal) shows lift information and COP with input adds floor selection. Where enabled, Floors edits shared labels, Access manages entrance-specific Floorpass codes and Reservation sets the reservation duration.


Connect locally over Gateway Wi-Fi

  1. Enable phone Wi-Fi. Stand beside the Gateway and open Connect → Gateway. Local access works without cloud sign-in.
  2. Hold FUN for at least 3 seconds and release before 6 seconds. Enter all eight spoken digits, including any leading zero.
  3. Accept the network prompt. On Android, enable location services and allow precise location if requested.
  4. In Controllers, select the expected elevator number. Refresh if needed. Go back from the list to release the local connection. Devices returns to cloud monitoring.
Local Gateway connection screen with an eight-digit PIN field.

If joining fails, check permissions and request a fresh PIN beside the intended Gateway. Connect favors the strongest nearby ONFUSE network.


Change settings and update devices

In Devices → your lift → Settings, verify Name, address, coordinates and language against the work order, then open Tools.

Gateway Settings with separate update actions for Gateway and Displays.
Tool What to check
Update Gateway software Confirm the update. After restart, check the result and Gateway version.
Update display software Targets all registered Displays that have identified themselves at least once. After restart, check each version.
Update Cabin logo Check the organization’s logo on each cabin screen.
Set automatic announcement Review the text, save and verify playback during the approved call test.
Update operation profile Retrieves an assigned office change. Check Actions.
Reset user PIN Clears the Gateway’s local PIN. A Display PIN requires its own service procedure.
Reboot Restarts the Gateway.
Reset to factory settings Physical confirmation erases local data. Recommission the Gateway afterward.

Did the action finish?

In Gateway → Actions → See more, open the request and tap Refresh. Open or In progress means pending. For Error, record the response and time before retrying. For Completed, verify the change on the device. Alerts includes test-call results.


Before leaving the site

  • Record the elevator number, site address, Gateway and Display IDs, and software versions.
  • Check fresh Gateway and controller data. Verify floor and direction in each cabin.
  • Follow the approved emergency-phone test. Confirm two-way audio with the operator. Record Gateway → Testing → Last successful test call and the matching Connect alert for the automatic test.
  • Check all requested actions. Record unresolved faults with the failed connection, message and time. Keep credentials and PINs out of screenshots and handover notes.

Troubleshoot power, live data or cloud connection

Last updated 6 days ago
Was this helpful?
Thanks!